Suzhou Dingyu Energy-Saving Equipment Co., Ltd. WINFAN · FRP FANS & WASTE GAS TREATMENT
EN 中文
TECHNICAL DATA

Technical Data & Fan Selection

Fan selection ranges and performance charts, SCR scrubbing tower specifications and adsorbent performance data, all from the Winfan catalogues. Selection data is for guidance only — every final selection is confirmed by our engineers.

TECHNICAL DATA

Technical Data & Fan Selection

Catalogue selection ranges for the FRP TF/HF series and the metal TDC/TAA series, from the Winfan fan catalogues (FRP Fan Series, November 2023; Metal Fan Series, April 2023). All figures are approximate (≈), read from the catalogue performance charts. Selection data for guidance only — final selection confirmed by our engineers.

TF Series — FRP Medium/Low-Pressure Fans

TF series summary of performance chart from the catalogue: static pressure against air flowrate for the TF fan sizes
TF series — Summary of Performance Chart (test temperature 20 °C). Catalogue worked example: 30,000 m³/h at 2,000 Pa static pressure selects model TF-331B.
TF series — selection range by size, belt drive (14 sizes, approximate)
ModelAirflow (≈ m³/h)Static pressure (≈ Pa)
TF-121B≈600–2,100≈100–1,600
TF-151B≈700–5,500≈300–2,100
TF-181B≈3,000–10,000≈300–2,700
TF-211B≈3,200–12,500≈300–2,700
TF-241B≈4,000–18,100≈300–2,700
TF-271B≈8,500–23,500≈300–2,700
TF-301B≈11,500–28,500≈900–2,700
TF-331B≈12,000–36,000≈900–2,700
TF-361B≈18,000–46,000≈900–2,700
TF-421B≈30,000–60,000≈900–2,700
TF-481B≈44,000–80,000≈900–2,700
TF-541B≈60,000–108,000≈900–2,700
TF-601B≈70,000–127,000≈900–2,700
TF-721B≈84,000–150,000≈1,200–2,700

Series envelope: airflow ≈600–150,000 m³/h, static pressure ≈100–2,700 Pa. Power (kW) ratings include drive losses; performance ratings do not include system effects of fan accessories (catalogue note). Selection data for guidance only — final selection confirmed by our engineers.

Catalogue design features of the FRP series: backward-inclined impeller with logarithmic-profile, high-strength formed blades; oil-cooled bearing housing for long bearing life, easy maintenance and low mechanical noise; casing and steel-frame fasteners integrally pre-embedded during moulding, so corrosion cannot destroy the fixings; 24-hour, year-round service support.

HF Series — FRP High-Pressure Fans

HF series summary of performance chart from the catalogue: static pressure against air flowrate for the HF fan sizes
HF series — Summary of Performance Chart (test temperature 20 °C). Catalogue worked example: 25,000 m³/h at 4,000 Pa static pressure selects model HF-421B.
HF series — selection envelope (approximate)
SizesAirflow (≈ m³/h)Static pressure (≈ Pa)
HF-121B – HF-721B (11 sizes)≈50–100,000≈400–5,900

For high-resistance corrosive-gas duty: wastewater deodorization, sludge drying, pharmaceutical chemicals, fibreglass production, rare-earth extraction, paper-mill anaerobic systems and acid recovery. Selection data for guidance only — final selection confirmed by our engineers.

TDC Series — Metal Centrifugal Fans (Coupling Drive)

TDC series combined performance chart from the metal fan catalogue: static pressure against airflow for sizes TDC-4.5 to TDC-18
TDC series — combined performance chart. Catalogue worked example: 30,000 m³/h at 2,500 Pa selects model TDC-10.
TDC series — selection envelope (approximate)
SizesAirflow (≈ m³/h)Static pressure (≈ Pa)
TDC-4.5 – TDC-18 (12 sizes)≈1,400–130,000≈1,000–5,200

Selection data for guidance only — final selection confirmed by our engineers.

TAA Series — Metal Centrifugal Fans

TAA series combined performance chart from the metal fan catalogue: static pressure against airflow for sizes TAA-3.2 to TAA-20
TAA series — combined performance chart, covering the widest airflow range of the metal fan line.
TAA series — selection envelope (approximate)
SizesAirflow (≈ m³/h)Static pressure (≈ Pa)
TAA-3.2 – TAA-20 (17 sizes)≈600–256,000≈450–4,200

Selection data for guidance only — final selection confirmed by our engineers.

How to Read a Model Number

FRP Fans (TF / HF)

B TF-241 B

  • Leading "B" — the complete fan set is explosion-proof. Without the B prefix, the fan is not whole-set explosion-proof (e.g. BTF-241B, BHF-301D).
  • TF / HF — TF = medium & low-pressure fan; HF = high-pressure fan.
  • Number — model / size (e.g. 241).
  • Final letter — drive mode: B = belt drive; C = drive via coupling; D = direct drive by motor shaft.

Examples: TF-151B — medium/low-pressure fan, size 151, belt drive. HF-181C — high-pressure fan, size 181, coupling drive.

Metal Fans (TDC / TAA)

TDC-8 C

  • TDC / TAA — metal centrifugal fan series; the TDC line is coupling-driven.
  • Number — impeller diameter in decimetres: TDC-8 is the ≈800 mm impeller class, TAA-20 the ≈2,000 mm class.
  • Final letter — drive mode: C = coupling drive, as used throughout the catalogue dimension tables (TDC-4C to TDC-18C; TAA-3.2C to TAA-20C).

Full per-size performance curves and dimension tables for all eight outlet directions are available in the catalogue — ask our engineers for the pages for your selected size.

A Note on the 12,000 Pa Figure

The maximum pressure of up to 12,000 Pa quoted on this page refers to Dingyu's custom ultra-high-pressure FRP fans — a separate, made-to-order line for ultra-high-resistance tail-gas systems. It is not part of the standard HF catalogue series above, whose selection envelope tops out at ≈5,900 Pa. If your system resistance is in that range, talk to our engineers about a custom selection.

SCR Vertical Scrubbing Towers — Specifications

SCR vertical scrubbing tower installed on a project site (photo)
SCR vertical scrubbing tower on a project site (actual photo)
SCR vertical scrubbing towers — full specification table (17 models)
ModelTower dia. A (mm)Tower height B (mm)Gas inlet C (mm)Packing depth D (mm)Demister depth F (mm)Circulation water (L/min)Airflow (m³/h)
SCR-6006004,3003001,200600702,000
SCR-8008004,4004001,2006001304,000
SCR-10001,0004,5004501,2006002006,000
SCR-12001,2004,6005501,2006002708,000
SCR-14001,4004,7006001,20060037011,000
SCR-16001,6004,8007001,20060049014,500
SCR-18001,8004,9008001,20060060018,000
SCR-20002,0005,0009001,20060077023,000
SCR-22002,2005,0001,0001,20060090027,000
SCR-24002,4005,0002000×4501,2006001,10033,000
SCR-26002,6005,1002000×6001,2006001,30038,000
SCR-28002,8005,2002000×6001,2006001,50044,000
SCR-30003,0005,3002200×6001,2006001,70051,000
SCR-32003,2005,4002300×7001,2006001,90058,000
SCR-34003,4005,5002400×8001,2006002,20065,000
SCR-36003,6005,6002600×8001,2006002,40073,000
SCR-38003,8005,7003200×8001,2006002,70082,000

Standard fittings (acid-mist towers): spray system, packing media, moisture separator, inspection window / access manhole, overflow, drain & auto-refill ports, pressure gauge. Options: pH control, ORP control, chemical storage tank, chemical level control, circulation-tank level control. Non-standard sizes can be made to order. Source: Dingyu Waste Gas Treatment Engineering Brochure (February 2025 edition).

Adsorbent Performance Data

Adsorbents for adsorption units — performance data (brochure)
AdsorbentForm / sizeDensity (kg/m³)Key performance
Pelleted activated carbonΦ4×8460–650Benzene adsorption 20–55%; carbon tetrachloride adsorption 30–70% (by iodine-value grade)
Honeycomb activated carbon100×100×100 mm, 1.5 mm cells250–380Benzene adsorption 30–70%; carbon tetrachloride adsorption 50–85%
SDG adsorbent, Type IΦ3×5-10650–750Adsorption capacity 25–35%; for NOx
SDG adsorbent, Type IIΦ3×5-10730–830Adsorption capacity 40–50%; for acid gases such as H₂SO₄, HCl and HF

Source: Dingyu Waste Gas Treatment Engineering Brochure (February 2025 edition), adsorption unit data table.

Contact Us

For equipment selection, system design and quotations, reach us in one tap — chat on WhatsApp or Messenger, or send an email. We reply directly.

CONTACT
Bono Xiong
WHATSAPP (BUSINESS)
FACEBOOK PAGE
ADDRESS
Suzhou Dingyu Energy-Saving Equipment Co., Ltd. · No. 4058 Linhu Avenue, Wujiang District, Suzhou, Jiangsu, China